Elevator v1.0.0 DriverInterface

Module is an interface between elevator server and executable

State:

  • No state

Tasks:

  • Communicating between server and program

Communication:

  • Sends to: Poller, StateMachine
  • Receives from: ElevatorServer

Link to this section Summary

Link to this section Functions

Link to this function

child_spec(init_arg)

Returns a specification to start this module under a supervisor.

See Supervisor.

Link to this function

get_floor_sensor_state(pid)

Link to this function

get_obstruction_switch_state(pid)

Link to this function

get_order_button_state(pid, floor, button_type)

Link to this function

get_stop_button_state(pid)

Invoked when the server is started. start_link/3 or start/3 will block until it returns.

init_arg is the argument term (second argument) passed to start_link/3.

Returning {:ok, state} will cause start_link/3 to return {:ok, pid} and the process to enter its loop.

Returning {:ok, state, timeout} is similar to {:ok, state} except handle_info(:timeout, state) will be called after timeout milliseconds if no messages are received within the timeout.

Returning {:ok, state, :hibernate} is similar to {:ok, state} except the process is hibernated before entering the loop. See c:handle_call/3 for more information on hibernation.

Returning {:ok, state, {:continue, continue}} is similar to {:ok, state} except that immediately after entering the loop the c:handle_continue/2 callback will be invoked with the value continue as first argument.

Returning :ignore will cause start_link/3 to return :ignore and the process will exit normally without entering the loop or calling c:terminate/2. If used when part of a supervision tree the parent supervisor will not fail to start nor immediately try to restart the GenServer. The remainder of the supervision tree will be started and so the GenServer should not be required by other processes. It can be started later with Supervisor.restart_child/2 as the child specification is saved in the parent supervisor. The main use cases for this are:

  • The GenServer is disabled by configuration but might be enabled later.
  • An error occurred and it will be handled by a different mechanism than the Supervisor. Likely this approach involves calling Supervisor.restart_child/2 after a delay to attempt a restart.

Returning {:stop, reason} will cause start_link/3 to return {:error, reason} and the process to exit with reason reason without entering the loop or calling c:terminate/2.

Callback implementation for GenServer.init/1.

Link to this function

set_door_open_light(pid, state)

Link to this function

set_floor_indicator(pid, floor)

Link to this function

set_motor_direction(pid, direction)

Link to this function

set_order_button_light(pid, button_type, floor, state)

Link to this function

set_stop_button_light(pid, state)

Link to this function

start(address, port)

Link to this function

start_link(list \\ [{127, 0, 0, 1}, 15657])